MyAdvantech Registration

MyAdvantech is a personalized portal for Advantech customers. By becoming an Advantech member, you can receive latest product news, webinar invitations and special eStore offers.

Sign up today to get 24/7 quick access to your account information.

Class I, Division 2 Solution

Class I, Division2 remote I/Os, such as CID1 monitors and CID2 solutions, have met the requirements of hazardous area computer such as explosion proof, oil field drilling, pump station monitoring, chemical plants, pharmaceutical factories, oil pipeline monitoring, tank storage monitoring, and fuel station management. Class I, Division 2 remote I/O products include data acquisition modules, industrial Ethernet switches, serial device servers, industrial monitors and embedded automation computers, all the CID2 monitor and CID2 solution series are hazardous area computer and explosion poof.

Product Categories

  • Data Acquisition Modules

    Advantech's data acquisition modules and ethernet I/O modules provide ideal industrial control and measurement solutions for harsh environments and demanding applications. With wide operating temperature ranges and multiple mounting methods, Advantech's ADAM series, such as RS-485-based and ethernet I/O, can be implemented in diverse applications. The Advantech ADAM-3000 series consists of cost-efficient, field configurable, isolated signal conditioning modules that can be easily installed to protect instruments and signals from the harmful effects of electrical interference.

    • ADAM-4520

      Most industrial computer systems come with standard RS-232 serial ports. Though widely accepted, RS-232 has limited transmission speed, range, and networking capabilities. The RS-422 and RS-485 standards overcome these limitations by using differential voltage lines for data and control signals. The ADAM-4520/4522 converter lets you take advantage of RS-422 and RS-485 on systems originally equipped with RS-232. It transparently converts RS-232 signals into isolated RS-422 or RS-485 signals. You do not need to change your PC's hardware or your software. The ADAM-4520 lets you easily build an industrial grade, long distance communication system with standard PC hardware. It extends the communication distance by 4000 ft. (1200 m) or increases the maximum number of connected nodes by 32.
  • Industrial Communication

    Advantech is a global leader in industrial communication, industrial Ethernet managed/unmanaged switches, data acquisition (DAQ), industrial computer and control products which are widely used in laboratory and industrial automation applications such as: monitoring, motion control, data acquisition (DAQ), and automated testing. There are five major categories in industrial communication - PC/104, PCI-bus, ISA-bus, USB-based, and Compact PCI modules including USB modules, PC/104 modules, ISA cards, IO drivers, signal conditioning modules, terminal boards and Compact PCI system. With multiple wiring terminals and extensive software support, Advantech provides industrial Ethernet switched with reliable, efficient, and cost-saving industrial for computer solutions. Advantech's DAQ products could simply be bundled with versatile industrial PC chassis, backplanes, CPU modules, flat panel monitors and embedded automation computers

  • Industrial Monitor

    The FPM-8151H is a particularly rugged and reliable 15" XGA wide temperature industrial monitor for a variety of industry applications. Equipped with a wide operating temperature range of -20 ~ 60oC (-4 ~140oF), it can satisfy the demands of a wide range of harsh industrial applications. This industrial monitor model also features an enhanced 5-wire resistive touch and system isolation to enhance the reliability. Moreover, the FPM-8151H is designed to be safely operated in these locations and is undergoing certification to be UL listed for Hazardous Locations with Class I, Division 2.

    • FPM-8151H

      The FPM-8151H is a particularly rugged and reliable 15” XGA wide temperature industrial monitor for a variety of industry applications. Equipped with a wide operating temperature range of -20 ~ 60°C (-4 ~ 140°F), it can satisfy demands in a wide range of harsh industrial applications. This model also features enhanced 5-wire resistive touch and system isolation to enhance the reliability. Moreover, FPM-8151H is designed to be safely operated in these locations and is certified with UL Class I Division 2 for hazardous environment.
  • Embedded Automation Computers

    As a leading industrial automation solution provider, Advantech’s offers a complete range of embedded automation computers with each series coming in three sizes: palm, small and regular, all of them are dedicated to providing fanless, industrial-proven and application ready control platforms. With a robust design, they include multiple expansion solutions and versatile mounting way to fulfill the needs of different applications. The UNO-1000/3000 series is ideal for din-rail, enclsure and book mounting in control cabinet and the UNO-2000 series is a versatile model for stand mount environments. In addition, all of the new UNO product support Advantech iDoor Technology which is a brand-new design concept that utilizes the mini PCIe format, by using standardized modules and interfaces, iDoor Technology gives customers the flexibility to configure the various I/O requirements based on different applications. Modules for iDoor Technology include: Fieldbus protocol; digital and analog I/O; smart sensor, communication and memory.

    • UNO-1172AH

      In hazardous locations, devices are under potential danger from flammable gases, combustible dust, or ignitable fibers, creating the potential for fire and explosions. UNO-1172AH are designed to be safely operated in these locations and are UL listed for Hazardous Locations with Class I, Division 2, groups A, B, C, D & T5 certification. The UNO-1172AH is an Intel Atom DIN-rail PC which features an innovative system diagnosis feature for automation applications. They provide alarms for over temperature, over voltage, battery power fail, power status on both system onboard LED and Digital output. They also include remote power control through digital input. These system diagnosis features enable control and monitoring of system status remotely. Three Gigabit Ethernet interfaces with teaming function support allow users to uplink two ports with data transmission fault tolerance and downlink one port to field device.